About the Airborne Microbial Count Calculator
Monitoring the air for microbial contamination is a cornerstone of quality control in sterile manufacturing, cleanrooms, and healthcare settings. This Airborne Microbial Count Calculator is a specialized tool designed to simplify the interpretation of air sampling data, helping quality control professionals, microbiologists, and validation engineers ensure environmental standards are met.
What This Calculator Does
The calculator processes raw data from two primary air sampling methods to provide standardized, actionable results:
- Active Air Sampling: For devices that actively draw a known volume of air over a growth medium, the calculator computes the concentration of microorganisms, expressed as Colony Forming Units per cubic meter (CFU/m³).
- Passive Air Sampling (Settle Plates): For plates exposed to the environment for a set duration, the calculator provides the result as CFU per plate and calculates the microbial deposition rate (CFU/m²/hour), indicating the rate at which viable particles settle onto surfaces.
It also offers an optional "positive-hole correction" for active sampling, which adjusts for the statistical probability of multiple microbes passing through the same hole in the sampler head, providing a more accurate count on high-load plates.
When to Use It
This tool is essential for routine environmental monitoring and qualification activities in controlled environments, including:
- Pharmaceutical and biotechnology manufacturing facilities (in compliance with GMP).
- Sterile compounding pharmacies (following USP standards).
- Hospital operating rooms and isolation wards.
- Medical device manufacturing cleanrooms.
- Food and beverage processing areas.
- Validation of HVAC systems and HEPA filters.
Inputs Explained
Common Inputs
- Raw Colony Count (CFU): The number of distinct microbial colonies observed on the agar plate after incubation.
- Sample ID / Location: An optional identifier for traceability (e.g., "Cleanroom A," "LAF Hood #2").
Active Sampling Inputs
- Sampler Flow Rate: The calibrated rate at which the sampler draws air, typically in Liters per minute (L/min) or cubic meters per hour (m³/hr). A common rate is 100 L/min.
- Total Sampling Time: The duration the sampler was active. For a 1 m³ sample with a 100 L/min flow rate, this would be 10 minutes.
- Positive-Hole Correction: An optional adjustment based on the Feller correction formula. It requires the number of holes in the sampler head (e.g., 400 for a MAS-100 device). This is crucial for counts approaching 5-10% of the total number of holes.
Passive Sampling Inputs
- Plate Diameter: The diameter of the settle plate used, typically 90 mm or 150 mm. This is used to calculate the surface area.
- Total Exposure Time: The duration the plate was left exposed to the environment, commonly up to 4 hours as per GMP guidelines.
Results Explained
- Total Air Volume Sampled (m³): For active sampling, this is the total volume of air that passed over the agar plate.
- Microbial Concentration (CFU/m³): The primary result for active sampling, representing the number of viable microorganisms per cubic meter of air.
- Corrected Concentration (CFU/m³): If positive-hole correction is applied, this result provides a statistically adjusted, more accurate concentration.
- Result per Plate (CFU/plate): The primary result for passive sampling, simply the raw count. This is often the value compared against regulatory limits.
- Microbial Deposition Rate (CFU/m²/hour): A standardized metric for passive sampling that quantifies how many viable microbes are settling on surfaces over time.
Formula / Method
Active Sampling Formula
Concentration (CFU/m³) = Raw CFU / Total Volume Sampled (m³)
Where:
Total Volume (m³) = (Flow Rate (L/min) × Sampling Time (min)) / 1000
Positive-Hole Correction (Feller)
Probable Count (Pr) = N × ln(N / (N - r))
Where N is the number of holes in the sampler head and r is the raw colony count (CFU).
The corrected concentration is then: Corrected CFU/m³ = Pr / Total Volume (m³)
Passive Sampling Formula
Deposition Rate (CFU/m²/hr) = Raw CFU / (Plate Area (m²) × Exposure Time (hr))
Where:
Plate Area (m²) = π × (Plate Diameter (m) / 2)²
Step-by-Step Example
Example 1: Active Sampling
- Inputs:
- Raw CFU:
12 - Flow Rate:
100 L/min - Sampling Time:
10 min
- Raw CFU:
- Calculate Volume:
(100 L/min × 10 min) / 1000 = 1.0 m³ - Calculate Concentration:
12 CFU / 1.0 m³ = 12.0 CFU/m³
Example 2: Passive Sampling
- Inputs:
- Raw CFU:
3 - Plate Diameter:
90 mm(0.09 m) - Exposure Time:
4 hours
- Raw CFU:
- Calculate Area:
π × (0.09 m / 2)² ≈ 0.00636 m² - Calculate Deposition Rate:
3 CFU / (0.00636 m² × 4 hr) ≈ 118.0 CFU/m²/hr
Tips + Common Errors
- Sampler Calibration: Always ensure your active air sampler is within its calibration period. An inaccurate flow rate directly impacts the final concentration.
- Avoid Obstructions: Place the sampler in a representative location away from direct drafts, personnel traffic, or obstructions that could skew results.
- Handling Plates: Use aseptic technique when handling agar plates to prevent accidental contamination. Ensure plates are not expired and have been stored correctly.
- TNTC Plates: If a plate is "Too Numerous To Count" (typically >250 CFU), the result is invalid. Sampling time should be reduced in such areas. The calculator cannot be used for TNTC plates.
- Unit Consistency: Double-check that all units (minutes vs. hours, mm vs. cm) are entered correctly into the calculator to avoid significant errors.
Frequently Asked Questions (FAQs)
1. What is the difference between active and passive air sampling?
Active sampling is a quantitative method that uses a device to pull a known volume of air over a collection medium, yielding a result in CFU/m³. Passive sampling is a qualitative/semi-quantitative method that relies on gravity for microbes to settle onto an open agar plate, measuring deposition over time.
2. Why is positive-hole correction necessary?
On plates with many colonies, there's a statistical chance that two or more microbes passed through the same hole in the sampler head but only formed one visible colony. The Feller correction formula estimates the "true" count, preventing underestimation of contamination levels.
3. At what colony count should I apply the correction?
There's no universal rule, but it's generally recommended when the raw CFU count exceeds 5-10% of the total number of holes in your sampler's head. For a 400-hole sampler, you should consider it for counts above 20-40 CFU.
4. What are "Alert" and "Action" limits?
An "Alert" limit is a threshold that, when exceeded, indicates a potential drift from normal operating conditions and triggers increased monitoring or scrutiny. An "Action" limit is a higher threshold that, when exceeded, requires immediate investigation and corrective action (e.g., stop production, re-sanitize). This calculator uses a 50% threshold for the Alert level.
5. Can I use this calculator for USP <797> compliance?
Yes. The calculator includes limits based on USP <797> standards for sterile compounding environments. You can select the standard and the appropriate ISO class to compare your results against the specified action levels.
6. Why can't I expose a settle plate for more than 4 hours?
Prolonged exposure can cause the agar medium to dehydrate, reducing its ability to support microbial growth. Additionally, the efficacy of disinfectants or sanitizing agents incorporated into some media can diminish over time. EU GMP Annex 1 suggests a 4-hour maximum exposure.
7. What should I do if my CFU count is zero?
A result of 0 CFU is a valid and often desirable outcome, especially in Grade A / ISO 5 environments. It indicates no viable microorganisms were detected under the test conditions. The calculated concentration will be 0 CFU/m³.
8. Can this tool be used for fungal spore counts?
Yes, provided you are using a growth medium that supports fungal growth (e.g., Sabouraud Dextrose Agar - SDA). The principle of calculation is the same, but the result would be interpreted as fungal CFU/m³.
References
- EudraLex - Volume 4 - Good Manufacturing Practice (GMP) guidelines, Annex 1: Manufacture of Sterile Medicinal Products (2022). health.ec.europa.eu
- ISO 14644-1:2015, Cleanrooms and associated controlled environments — Part 1: Classification of air cleanliness by particle concentration. iso.org
- ISO 14698-1:2003, Cleanrooms and associated controlled environments — Biocontamination control — Part 1: General principles and methods. iso.org
- United States Pharmacopeia (USP). General Chapter <797> Pharmaceutical Compounding—Sterile Preparations. usp.org
- United States Pharmacopeia (USP). General Chapter <1116> Microbiological Control and Monitoring of Aseptic Processing Environments. uspnf.com

I am a Registered Pharmacist under the Pharmacy Act, 1948, and the founder of PharmacyFreak.com. I hold a Bachelor of Pharmacy degree from Rungta College of Pharmaceutical Science and Research. With a strong academic foundation and practical knowledge, I am committed to providing accurate, easy-to-understand content to support pharmacy students and professionals. My aim is to make complex pharmaceutical concepts accessible and useful for real-world application.