Management of electronic data in QA/QC is a critical subject for M.Pharm students preparing for roles in pharmaceutical quality systems. This blog presents focused multiple-choice questions that cover principles such as data integrity (ALCOA+), regulatory requirements (21 CFR Part 11, EU Annex 11), system validation, audit trails, access controls, backup and archival strategies, electronic signatures, and procedural controls. Questions are designed to test applied knowledge required for implementing, monitoring, and auditing electronic data in laboratories and manufacturing quality systems. Practicing these MCQs will help students deepen understanding of technical, procedural, and regulatory aspects essential to ensure reliable, reproducible and compliant electronic records in pharmaceutical environments.
Q1. Which principle of data integrity emphasizes that data should be attributable, legible, contemporaneous, original and accurate?
- GAMP
- ALCOA
- CSV
- ISO 9001
Correct Answer: ALCOA
Q2. Which regulation specifically governs electronic records and electronic signatures for FDA-regulated industries?
- EU Annex 11
- ICH Q7
- 21 CFR Part 11
- GMP Annex 1
Correct Answer: 21 CFR Part 11
Q3. In the context of computerized system validation (CSV), what is the primary objective of User Requirements Specification (URS)?
- Describe the software code structure
- List the validation test scripts
- Define what the user needs the system to do
- Record daily system logs
Correct Answer: Define what the user needs the system to do
Q4. Which of the following is NOT part of ALCOA+ principles?
- Complete
- Original
- Accessible
- Confidential
Correct Answer: Confidential
Q5. What is the main purpose of an audit trail in an electronic quality system?
- To store backup copies
- To track and record changes to data and who made them
- To encrypt data at rest
- To prevent network access
Correct Answer: To track and record changes to data and who made them
Q6. According to EU Annex 11, what must be ensured for electronic signatures to be acceptable?
- They are printed on paper once a month
- They are unique to an individual and linked to their identity
- They are used only for internal memos
- They require no authentication
Correct Answer: They are unique to an individual and linked to their identity
Q7. Which control reduces risk of unauthorized changes in a Laboratory Information Management System (LIMS)?
- Open network access for all users
- Role-based access control with least privilege
- Using default vendor passwords indefinitely
- Storing raw data only on local analyst PCs
Correct Answer: Role-based access control with least privilege
Q8. What is the best practice for retention of electronic raw data in QA/QC labs?
- Retain only summary reports and delete raw data
- Retain original raw data with metadata and ensure secure archival
- Print raw data and destroy electronic copies immediately
- Keep raw data on analyst personal devices
Correct Answer: Retain original raw data with metadata and ensure secure archival
Q9. Which of the following is a key requirement when migrating legacy electronic data to a new system?
- Ignore metadata and only transfer PDF reports
- Validate migration to ensure completeness, integrity and traceability of data and metadata
- Migrate during peak production without testing
- Allow automatic deletion of source data after migration without verification
Correct Answer: Validate migration to ensure completeness, integrity and traceability of data and metadata
Q10. What is the role of the system owner in electronic data management?
- Write all laboratory SOPs alone
- Ensure system validation, data integrity, access control and ongoing maintenance
- Perform all routine backups personally
- Approve reagent purchases only
Correct Answer: Ensure system validation, data integrity, access control and ongoing maintenance
Q11. Which activity is essential to demonstrate suitability of a computerized system for its intended use?
- CSV including IQ/OQ/PQ
- Only vendor demonstrations
- Daily manual overrides
- Ad-hoc changes without documentation
Correct Answer: CSV including IQ/OQ/PQ
Q12. What does the acronym ‘CSV’ commonly stand for in pharmaceutical QA/QC contexts?
- Computer System Validation
- Critical Sample Volume
- Certified Standard Verification
- Controlled Storage Version
Correct Answer: Computer System Validation
Q13. Which of the following best describes ‘metadata’ in electronic laboratory records?
- The printed paper copies of reports
- Data about the data such as timestamps, instrument ID and operator
- A type of encryption algorithm
- Only the numerical results in a table
Correct Answer: Data about the data such as timestamps, instrument ID and operator
Q14. What is a key component of data backup strategy for QA/QC electronic systems?
- Single local backup on the same server
- Regularly scheduled, tested offsite/backups with verified restore procedures
- Backup only when convenient
- Never test restores to avoid risks
Correct Answer: Regularly scheduled, tested offsite/backups with verified restore procedures
Q15. In the event of an electronic data discrepancy, which step should be taken first?
- Immediately delete the record
- Perform a documented investigation to determine root cause and impact
- Ignore it if results look acceptable
- Change the data to match expectations without record
Correct Answer: Perform a documented investigation to determine root cause and impact
Q16. Which control ensures that only authorized personnel can electronically sign a document?
- Open guest accounts
- Multi-factor authentication tied to individual credentials
- Shared generic passwords
- Using analyst initials written on paper only
Correct Answer: Multi-factor authentication tied to individual credentials
Q17. Which one describes the ‘review and approval’ function in an electronic QC workflow?
- Automatic deletion of failed tests
- Formal electronic sign-off with audit trail proving reviewer identity and timestamp
- Allowing any user to mark results reviewed without logs
- Disabling audit trails during review
Correct Answer: Formal electronic sign-off with audit trail proving reviewer identity and timestamp
Q18. For laboratory instrument data captured electronically, what is considered best practice regarding raw chromatographic data?
- Store only peak tables and discard raw data files
- Retain original raw data files, associated metadata and processing methods
- Convert raw files to screenshots only
- Allow analysts to edit raw files without traceability
Correct Answer: Retain original raw data files, associated metadata and processing methods
Q19. What is the recommended action when changes to validated computerized systems are required?
- Implement changes immediately without assessment
- Use change control to assess impact, re-validate affected functions and document changes
- Allow vendor to change system without documentation
- Ignore regulatory expectations for revalidation
Correct Answer: Use change control to assess impact, re-validate affected functions and document changes
Q20. How should access to electronic data be logged to meet data integrity requirements?
- No logs are necessary if users are trusted
- Comprehensive audit logs recording user ID, action, date/time and reason for changes
- Logs that can be edited by any user
- Logs stored only on the user’s workstation
Correct Answer: Comprehensive audit logs recording user ID, action, date/time and reason for changes

I am a Registered Pharmacist under the Pharmacy Act, 1948, and the founder of PharmacyFreak.com. I hold a Bachelor of Pharmacy degree from Rungta College of Pharmaceutical Science and Research. With a strong academic foundation and practical knowledge, I am committed to providing accurate, easy-to-understand content to support pharmacy students and professionals. My aim is to make complex pharmaceutical concepts accessible and useful for real-world application.